Heating Element MCQs — Set 5

10 practice questions on heating element failure and testing — continuity checks, insulation tests and common faults.

Q1. A heater is switched on but produces no heat, and the supply is confirmed live. A multimeter across the element shows infinite resistance. What is the fault?

  • (a) The element is short-circuited
  • (b) The element is open-circuited (burnt out)
  • (c) The thermostat is set too high
  • (d) The supply voltage is too high

Answer: (b) The element is open-circuited (burnt out) — infinite resistance means the nichrome wire has broken, so no current can flow.

Q2. An insulation resistance (megger) test on a geyser element shows a very low reading between the element terminals and the metal tank. What does this mean?

  • (a) The element is healthy
  • (b) The insulation has failed and current is leaking to earth
  • (c) The thermostat is faulty
  • (d) The element resistance is too high

Answer: (b) The insulation has failed and current is leaking to earth — low insulation resistance means the MgO or sheath insulation is damaged, which is a shock hazard.

Q3. Limescale builds up on an immersion heater element in hard-water areas. What problem does this cause?

  • (a) The element heats water faster
  • (b) The scale insulates the element, so it overheats internally and fails early
  • (c) The scale reduces the supply voltage
  • (d) The scale makes the water colder

Answer: (b) The scale insulates the element, so it overheats internally and fails early — heat cannot escape into the water, so the element’s own temperature climbs until it burns out.

Q4. What is “dry firing” of an immersion heater?

  • (a) Running the heater with no water around the element
  • (b) Running the heater on a low voltage
  • (c) Testing the heater with a megger
  • (d) Running the heater with cold water

Answer: (a) Running the heater with no water around the element — without water to carry the heat away, the element overheats and burns out in seconds.

Q5. A 1,000 W, 230 V element is tested with a multimeter. What resistance reading shows it is healthy?

  • (a) About 0 Ω
  • (b) About 52.9 Ω
  • (c) About 230 Ω
  • (d) Infinite resistance

Answer: (b) About 52.9 Ω — R = V² ÷ P = 230² ÷ 1,000 = 52.9 Ω; near-zero means a short, infinite means open circuit.

Q6. A heater keeps tripping the 30 mA RCCB as soon as it is switched on. What is the most likely cause?

  • (a) The thermostat is set too low
  • (b) The element has an earth fault — current is leaking from the element to the earthed body
  • (c) The supply voltage is too low
  • (d) The element is too powerful

Answer: (b) The element has an earth fault — current is leaking from the element to the earthed body — the RCCB detects the leakage above 30 mA and trips to prevent a shock.

Q7. Hot spots form on a heating coil where the turns are bunched together. Why do hot spots shorten the element’s life?

  • (a) They make the element draw less current
  • (b) The local temperature is much higher, so the wire oxidises and thins faster there
  • (c) They increase the supply voltage
  • (d) They cool the rest of the element

Answer: (b) The local temperature is much higher, so the wire oxidises and thins faster there — the thinned wire gets hotter still, until it breaks.

Q8. A 1,000 W element rated at 230 V is connected to a 240 V supply. What power does it now draw?

  • (a) 1,000 W
  • (b) 1,089 W
  • (c) 960 W
  • (d) 1,200 W

Answer: (b) 1,089 W — P = V² ÷ R = 240² ÷ 52.9 = 57,600 ÷ 52.9 = 1,089 W; the extra power runs the element hotter and shortens its life.

Q9. The metal sheath of a tubular element is corroded and cracked. What is the danger?

  • (a) The element will heat faster
  • (b) Water or air can reach the live coil and MgO, causing an earth fault or shock
  • (c) The thermostat will stop working
  • (d) The supply fuse will get larger

Answer: (b) Water or air can reach the live coil and MgO, causing an earth fault or shock — a damaged sheath destroys the insulation barrier, so the element must be replaced.

Q10. Before testing a heating element with a multimeter, what is the first safety step?

  • (a) Turn the thermostat to maximum
  • (b) Switch off and isolate the supply, then confirm it is dead
  • (c) Pour water on the element
  • (d) Hold the element while testing

Answer: (b) Switch off and isolate the supply, then confirm it is dead — resistance and continuity tests are done on a dead circuit to avoid shock and false readings.