Q1. What is a passive harmonic filter?
- (a) A series inductor-capacitor circuit tuned to offer a low-impedance path at one harmonic frequency
- (b) A device that injects an equal and opposite harmonic current
- (c) A larger transformer with no filter components
- (d) A circuit breaker that trips on harmonics
Answer: (a) A series inductor-capacitor circuit tuned to offer a low-impedance path at one harmonic frequency — the tuned LC branch shunts that harmonic away from the supply.
Q2. A passive filter is tuned to the 5th harmonic (250 Hz on a 50 Hz system). Which harmonic does it mainly remove?
- (a) The 3rd harmonic
- (b) The 5th harmonic
- (c) The 7th harmonic
- (d) The fundamental
Answer: (b) The 5th harmonic — a tuned filter has its lowest impedance at its tuned frequency, so it absorbs mainly that harmonic.
Q3. How does an active harmonic filter work?
- (a) It measures the harmonic current and injects an equal current in the opposite phase to cancel it
- (b) It disconnects the load whenever harmonics appear
- (c) It adds a capacitor in series with the load
- (d) It increases the supply voltage to swamp the harmonics
Answer: (a) It measures the harmonic current and injects an equal current in the opposite phase to cancel it — the injected current cancels the harmonic at the point of connection.
Q4. What is the main advantage of an active filter over a passive filter?
- (a) It adapts automatically to changing loads and several harmonic orders at once
- (b) It is always cheaper than a passive filter
- (c) It needs no power supply of its own
- (d) It can only filter one fixed harmonic
Answer: (a) It adapts automatically to changing loads and several harmonic orders at once — a passive filter is fixed to one tuned frequency, while an active filter tracks the load.
Q5. What does a line reactor (AC choke) do when fitted in front of a VFD?
- (a) It smooths the pulsed input current and reduces harmonic distortion
- (b) It increases the harmonic current drawn by the drive
- (c) It converts the drive output to DC
- (d) It replaces the drive’s rectifier
Answer: (a) It smooths the pulsed input current and reduces harmonic distortion — the added inductance slows the current pulses, lowering the harmonic content.
Q6. Compared with a 6-pulse rectifier, what is the main harmonic benefit of a 12-pulse rectifier?
- (a) It eliminates the 5th and 7th harmonics, leaving mainly the 11th and 13th
- (b) It produces larger 5th and 7th harmonics
- (c) It produces only triplen harmonics
- (d) It has no effect on harmonics at all
Answer: (a) It eliminates the 5th and 7th harmonics, leaving mainly the 11th and 13th — a 12-pulse rectifier generates harmonics of order 12k ± 1, so the lowest are the 11th and 13th, which are smaller.
Q7. What does a phase-shifting transformer do in harmonic mitigation?
- (a) It shifts the phase of one rectifier so its 5th and 7th harmonics cancel those of another
- (b) It steps the voltage up to remove harmonics
- (c) It stores harmonic energy in its core
- (d) It converts single-phase to three-phase
Answer: (a) It shifts the phase of one rectifier so its 5th and 7th harmonics cancel those of another — two rectifiers fed 30° apart cancel each other’s 5th and 7th harmonics, forming a 12-pulse system.
Q8. Why is a detuned reactor fitted in series with a power-factor correction capacitor?
- (a) To shift the resonance frequency away from a harmonic so the capacitor does not amplify it
- (b) To increase the capacitance of the bank
- (c) To make the capacitor absorb more harmonic current
- (d) To raise the supply voltage
Answer: (a) To shift the resonance frequency away from a harmonic so the capacitor does not amplify it — the reactor moves the series resonance below the lowest harmful harmonic, usually the 5th.
Q9. In a building with heavy single-phase electronic loads, what neutral sizing is commonly recommended?
- (a) A neutral rated at 200% of the phase conductor, to carry the added triplen current
- (b) A neutral half the size of the phase conductor
- (c) No neutral at all
- (d) A neutral the same size as the earth wire only
Answer: (a) A neutral rated at 200% of the phase conductor, to carry the added triplen current — triplen currents add in the neutral, so it can carry more current than a phase conductor.
Q10. How does a delta-wye transformer help reduce triplen harmonics on the supply side?
- (a) The delta winding traps triplen currents so they do not flow back into the supply
- (b) It converts triplen harmonics into the fundamental
- (c) It doubles the triplen current on the supply
- (d) It only works on the 5th harmonic
Answer: (a) The delta winding traps triplen currents so they do not flow back into the supply — triplen currents circulate in the closed delta and are blocked from the primary side.