Fuse MCQs — Set 10
10 practice questions on fuse selection and sizing — plug fuses, the NEC 80% rule and common fuse faults — with worked answers.
Q1. A 1,000 W appliance runs on 230 V. Which UK plug fuse should be fitted?
- (a) 3 A
- (b) 5 A
- (c) 13 A
- (d) 1 A
Answer: (c) 13 A — the appliance draws 1,000 ÷ 230 = 4.35 A, which is above the 3 A fuse range, so a 13 A fuse is fitted.
Q2. A 460 W lamp runs on 230 V. Which plug fuse is suitable?
- (a) 13 A
- (b) 3 A
- (c) 30 A
- (d) 1 A
Answer: (b) 3 A — the lamp draws 460 ÷ 230 = 2 A, so the 3 A fuse (for loads up to about 720 W) is correct.
Q3. A 2,300 W kettle runs on 230 V. Which plug fuse is suitable?
- (a) 3 A
- (b) 5 A
- (c) 13 A
- (d) 2 A
Answer: (c) 13 A — the kettle draws 2,300 ÷ 230 = 10 A, so a 13 A fuse is needed.
Q4. What is the fusing factor of a fuse?
- (a) The ratio of minimum fusing current to rated current
- (b) The ratio of rated current to minimum fusing current
- (c) The time a fuse takes to blow
- (d) The voltage rating of the fuse
Answer: (a) The ratio of minimum fusing current to rated current — fusing factor = minimum fusing current ÷ rated current, and it is always more than 1.
Q5. Under the NEC 80% rule, what is the maximum continuous load on a 15 A, 120 V circuit?
- (a) 1,800 W
- (b) 1,440 W
- (c) 1,200 W
- (d) 960 W
Answer: (b) 1,440 W — 15 A × 120 V × 0.8 = 1,440 W.
Q6. Under the NEC 80% rule, what is the maximum continuous load on a 30 A, 240 V circuit?
- (a) 7,200 W
- (b) 5,760 W
- (c) 3,600 W
- (d) 2,880 W
Answer: (b) 5,760 W — 30 A × 240 V × 0.8 = 5,760 W.
Q7. A fuse keeps blowing as soon as a new one is fitted. What is the most likely cause?
- (a) The fuse rating is too high
- (b) An overload or short circuit in the circuit
- (c) The supply voltage is too low
- (d) The fuse is too new
Answer: (b) An overload or short circuit in the circuit — the fuse is doing its job; the fault in the circuit must be found and fixed.
Q8. What is the danger of fitting a fuse of a much higher rating than specified?
- (a) The fuse will blow too often
- (b) The cable may overheat and catch fire before the fuse blows
- (c) The voltage will drop
- (d) The load will draw less current
Answer: (b) The cable may overheat and catch fire before the fuse blows — the fuse no longer protects the cable it was chosen for.
Q9. Why should a fuse never be fitted in the neutral conductor?
- (a) The neutral carries no current
- (b) After the fuse blows, the appliance would remain live at supply voltage
- (c) The fuse would blow instantly
- (d) The neutral wire is too thick
Answer: (b) After the fuse blows, the appliance would remain live at supply voltage — the live wire would still be connected, creating a shock risk.
Q10. A motor draws a large current for a second at switch-on. Which fuse should be used?
- (a) A fast-acting fuse
- (b) A time-delay (slow-blow) fuse
- (c) A rewirable fuse with thin wire
- (d) No fuse at all
Answer: (b) A time-delay (slow-blow) fuse — it rides through the brief starting surge but still blows on a real overload.