Fire Alarm MCQs — Set 8

10 practice questions on fire alarm testing, maintenance and false alarms — keeping the system reliable — with answers and explanations.

Q1. How often should a manual call point be tested in a routine weekly test?

  • (a) Once a year
  • (b) Once a month
  • (c) Once a week, using a different call point each time
  • (d) Only after a real fire

Answer: (c) Once a week, using a different call point each time — rotating the test proves every call point and sounder circuit over time.

Q2. How is a smoke detector tested without a real fire?

  • (a) By heating it with a lighter
  • (b) By spraying approved test smoke into it
  • (c) By pouring water on it
  • (d) By switching the panel off and on

Answer: (b) By spraying approved test smoke into it — the test aerosol simulates smoke entering the sensing chamber.

Q3. Which of these is a common cause of false alarms?

  • (a) A properly installed heat detector in a kitchen
  • (b) Steam, dust or cooking fumes entering a smoke detector
  • (c) A fully charged battery
  • (d) A weekly call-point test

Answer: (b) Steam, dust or cooking fumes entering a smoke detector — the detector cannot tell these apart from real smoke.

Q4. Why should smoke detectors be kept clean?

  • (a) Because dust inside the detector can cause false alarms or reduce its sensitivity
  • (b) Because a dirty detector uses more power
  • (c) Because dust makes the sounder quieter
  • (d) Because the panel cannot see a dirty detector

Answer: (a) Because dust inside the detector can cause false alarms or reduce its sensitivity — contamination changes how the detector responds.

Q5. What is the fire alarm log book used for?

  • (a) Recording tests, faults, false alarms and maintenance visits
  • (b) Recording the building’s electricity bills
  • (c) Recording staff holidays
  • (d) Recording the temperature in each room

Answer: (a) Recording tests, faults, false alarms and maintenance visits — the log proves the system is tested and maintained.

Q6. What is the best way to reduce false alarms in a dusty workshop?

  • (a) Fit more smoke detectors
  • (b) Use heat detectors instead of smoke detectors in the dusty area
  • (c) Switch the system off during working hours
  • (d) Fit louder sounders

Answer: (b) Use heat detectors instead of smoke detectors in the dusty area — heat detectors ignore dust, while smoke detectors would alarm on it.

Q7. Why is a full service of the fire alarm system carried out by a competent person at regular intervals?

  • (a) To change the colour of the cables
  • (b) To check every device, the battery and the panel so hidden faults are found before a real fire
  • (c) To make the sounders louder
  • (d) To reduce the number of detectors

Answer: (b) To check every device, the battery and the panel so hidden faults are found before a real fire — a fault that is never found is a failure waiting to happen.

Q8. What should be done after a false alarm?

  • (a) Ignore it completely
  • (b) Find and record the cause, and fix it if possible
  • (c) Remove the detector that operated
  • (d) Switch the system off for a week

Answer: (b) Find and record the cause, and fix it if possible — repeated false alarms make people ignore real alarms.

Q9. What happens to a detector’s sensitivity if it slowly fills with dust over months?

  • (a) It stays exactly the same
  • (b) It drifts — it may become over-sensitive and false-alarm, or under-sensitive and respond late
  • (c) It stops using power
  • (d) It becomes a heat detector

Answer: (b) It drifts — it may become over-sensitive and false-alarm, or under-sensitive and respond late — this is why cleaning and sensitivity checks matter.

Q10. Why must staff be told before a planned fire alarm test?

  • (a) So they can switch the system off
  • (b) So they know the alarm is a test and do not evacuate unnecessarily or panic
  • (c) So they can leave the building for the day
  • (d) So they can test the detectors themselves

Answer: (b) So they know the alarm is a test and do not evacuate unnecessarily or panic — a surprise test can cause disruption and injuries.