Fire Alarm MCQs — Set 5

10 practice questions on fire alarm warning devices — sounders, beacons and manual call points — with answers and explanations.

Q1. What is the purpose of a fire alarm sounder?

  • (a) To detect smoke
  • (b) To give an audible warning so occupants evacuate
  • (c) To charge the battery
  • (d) To detect a rise in temperature

Answer: (b) To give an audible warning so occupants evacuate — the sounder is the device people hear.

Q2. What is the typical minimum sound level required from a fire alarm sounder in general areas?

  • (a) 45 dB(A)
  • (b) 55 dB(A)
  • (c) 65 dB(A)
  • (d) 95 dB(A)

Answer: (c) 65 dB(A) — a typical minimum requirement so the alarm is heard above normal background noise.

Q3. In sleeping areas, what sound level is typically required at the bedhead?

  • (a) 55 dB(A)
  • (b) 65 dB(A)
  • (c) 75 dB(A)
  • (d) 100 dB(A)

Answer: (c) 75 dB(A) — a typical requirement at the bedhead so the alarm wakes sleeping occupants.

Q4. What is a fire alarm beacon?

  • (a) A flashing visual warning device
  • (b) A type of smoke detector
  • (c) A battery charger
  • (d) A manual call point

Answer: (a) A flashing visual warning device — beacons warn people who cannot hear the sounders.

Q5. Where are visual beacons especially needed?

  • (a) In quiet offices
  • (b) In noisy areas and where deaf or hard-of-hearing people may be present
  • (c) In outdoor car parks only
  • (d) In rooms with no doors

Answer: (b) In noisy areas and where deaf or hard-of-hearing people may be present — a flashing light is seen where a sounder may not be heard.

Q6. What is a manual call point?

  • (a) A device that detects smoke automatically
  • (b) A device a person operates by hand to raise the alarm
  • (c) A battery test button
  • (d) A fire extinguisher

Answer: (b) A device a person operates by hand to raise the alarm — it lets anyone who discovers a fire warn the whole building.

Q7. How is a break-glass manual call point operated?

  • (a) By pressing a button on the panel
  • (b) By breaking the glass (or pressing the frangible element) with a finger or thumb
  • (c) By blowing smoke into it
  • (d) By heating it with a match

Answer: (b) By breaking the glass (or pressing the frangible element) with a finger or thumb — this triggers the alarm circuit.

Q8. Where should manual call points be fitted?

  • (a) In the middle of large rooms only
  • (b) On escape routes, near exits and stairways
  • (c) Inside locked cupboards
  • (d) On the roof

Answer: (b) On escape routes, near exits and stairways — people reach them easily while leaving the building.

Q9. Why should the fire alarm sounder tone be different from other alarm tones in the building?

  • (a) So it uses less power
  • (b) So occupants recognise it immediately as the fire alarm and do not confuse it with another warning
  • (c) So it is cheaper to install
  • (d) So the battery lasts longer

Answer: (b) So occupants recognise it immediately as the fire alarm and do not confuse it with another warning — a distinct tone avoids delay in evacuation.

Q10. What is a combined sounder-beacon unit?

  • (a) A unit that gives both an audible sound and a flashing light warning
  • (b) A unit that detects both smoke and heat
  • (c) A unit that combines the panel and the battery
  • (d) A unit that combines two call points

Answer: (a) A unit that gives both an audible sound and a flashing light warning — one device covers both hearing and visual warning.