Fan MCQs — Set 9
10 practice questions on fan installation and safety — mounting, earthing, circuit loading and clearances — with answers.
Q1. What is the minimum safe height for ceiling fan blades above the floor?
- (a) 5 ft (1.5 m)
- (b) 7 ft (2.1 m)
- (c) 10 ft (3.0 m)
- (d) 12 ft (3.6 m)
Answer: (b) 7 ft (2.1 m) — blades lower than this are a head-injury risk; 7 ft is the standard minimum clearance.
Q2. What must the ceiling hook or mounting bracket of a ceiling fan be fixed to?
- (a) The plasterboard ceiling only
- (b) A ceiling joist or a concrete ceiling anchor strong enough to carry the fan’s weight
- (c) The light fitting
- (d) The curtain rail
Answer: (b) A ceiling joist or a concrete ceiling anchor strong enough to carry the fan’s weight — a fan must never hang from plasterboard alone, or it can fall.
Q3. Why must the metal body of a ceiling fan be earthed?
- (a) To make the fan run faster
- (b) So that a fault current trips the breaker instead of leaving the body live and giving a shock
- (c) To reduce the fan’s noise
- (d) To save electricity
Answer: (b) So that a fault current trips the breaker instead of leaving the body live and giving a shock — earthing gives fault current a safe path to trip the protective device.
Q4. A 30 mA RCCB is fitted on a circuit that supplies ceiling fans. What does it protect against?
- (a) Overloading the circuit
- (b) Electric shock from earth leakage current
- (c) Low voltage
- (d) Fan wobble
Answer: (b) Electric shock from earth leakage current — a 30 mA RCCB trips when leakage current reaches 30 mA, protecting people from shock.
Q5. What is the job of the capacitor in a single-phase ceiling fan motor?
- (a) To store energy for the light
- (b) To create the phase shift that starts the motor and sets its direction
- (c) To reduce the fan speed
- (d) To protect the motor against overload
Answer: (b) To create the phase shift that starts the motor and sets its direction — a single-phase motor cannot start on its own, so the capacitor shifts the current in the starting winding.
Q6. What should you do before working on a ceiling fan’s wiring?
- (a) Run the fan at full speed first
- (b) Switch off and isolate the supply at the breaker and check it is dead
- (c) Hold the blades still by hand
- (d) Switch the regulator to the lowest speed
Answer: (b) Switch off and isolate the supply at the breaker and check it is dead — never work on live fan wiring; isolation prevents electric shock.
Q7. How much clearance should ceiling fan blades have from the nearest wall?
- (a) No clearance is needed
- (b) At least 18 inches (45 cm)
- (c) At least 6 inches (15 cm)
- (d) At least 5 ft (1.5 m)
Answer: (b) At least 18 inches (45 cm) — blades too close to a wall cannot move air properly and may hit the wall if the fan wobbles.
Q8. Can an ordinary indoor ceiling fan be installed on an uncovered outdoor porch?
- (a) Yes, any fan works outdoors
- (b) No — only a fan rated for damp or wet locations should be used outdoors
- (c) Yes, if it is painted
- (d) Yes, if it is run at low speed
Answer: (b) No — only a fan rated for damp or wet locations should be used outdoors — rain and moisture will damage an indoor fan and create a shock risk.
Q9. Which colour is the earth wire in a fan’s supply cable?
- (a) Brown
- (b) Blue
- (c) Green and yellow
- (d) Red
Answer: (c) Green and yellow — the green-and-yellow wire is the earth (protective) conductor; brown is live and blue is neutral.
Q10. Before mounting a ceiling fan, what should you check about the ceiling?
- (a) Its colour
- (b) That the ceiling structure can safely bear the fan’s weight and vibration
- (c) That it has a light fitting
- (d) That it is freshly painted
Answer: (b) That the ceiling structure can safely bear the fan’s weight and vibration — a fan adds weight and constant vibration, so the mounting point must be sound.
Also read: Electrical Safety MCQs | All MCQ Topics