Q1. What does CFM stand for when rating a fan?

  • (a) Cubic feet per minute
  • (b) Current flow per metre
  • (c) Capacitor frequency per minute
  • (d) Cooling factor per metre

Answer: (a) Cubic feet per minute — CFM measures how much air a fan moves each minute; a higher CFM means more airflow.

Q2. What is the formula for the CFM needed to ventilate a room?

  • (a) CFM = room volume × air changes per hour ÷ 60
  • (b) CFM = room area × 60 ÷ air changes per hour
  • (c) CFM = room volume + air changes per hour
  • (d) CFM = room area × ceiling height × 60

Answer: (a) CFM = room volume × air changes per hour ÷ 60 — volume in cubic feet times the air changes per hour, divided by 60 minutes, gives cubic feet per minute.

Q3. A room is 100 sq ft with a 10 ft ceiling and needs 6 air changes per hour. What CFM is required?

  • (a) 60 CFM
  • (b) 100 CFM
  • (c) 600 CFM
  • (d) 1,000 CFM

Answer: (b) 100 CFM — volume = 100 × 10 = 1,000 cu ft; 1,000 × 6 = 6,000 cu ft per hour; 6,000 ÷ 60 = 100 CFM.

Q4. A room is 150 sq ft with a 10 ft ceiling and needs 6 air changes per hour. What CFM is required?

  • (a) 90 CFM
  • (b) 120 CFM
  • (c) 150 CFM
  • (d) 250 CFM

Answer: (c) 150 CFM — volume = 150 × 10 = 1,500 cu ft; 1,500 × 6 = 9,000 cu ft per hour; 9,000 ÷ 60 = 150 CFM.

Q5. A room is 200 sq ft with a 10 ft ceiling and needs 6 air changes per hour. What CFM is required?

  • (a) 120 CFM
  • (b) 200 CFM
  • (c) 300 CFM
  • (d) 1,200 CFM

Answer: (b) 200 CFM — volume = 200 × 10 = 2,000 cu ft; 2,000 × 6 = 12,000 cu ft per hour; 12,000 ÷ 60 = 200 CFM.

Q6. If the ceiling height of a room doubles while the floor area and air changes per hour stay the same, what happens to the required CFM?

  • (a) It stays the same
  • (b) It doubles
  • (c) It halves
  • (d) It quadruples

Answer: (b) It doubles — doubling the height doubles the room volume, and CFM is proportional to volume.

Q7. What does a higher CFM rating on an exhaust fan mean in practice?

  • (a) The fan uses less electricity
  • (b) The fan moves more air and clears smoke or steam faster
  • (c) The fan is quieter
  • (d) The fan lasts longer

Answer: (b) The fan moves more air and clears smoke or steam faster — CFM is the airflow rate, so a higher CFM clears a room more quickly.

Q8. A bathroom is 50 sq ft. Using the rule of thumb of 1 CFM per sq ft, what size exhaust fan is needed?

  • (a) 25 CFM
  • (b) 50 CFM
  • (c) 100 CFM
  • (d) 500 CFM

Answer: (b) 50 CFM — 50 sq ft × 1 CFM per sq ft = 50 CFM, enough to clear steam and moisture from the bathroom.

Q9. Why does a kitchen need more air changes per hour than a bedroom?

  • (a) Kitchens are always larger
  • (b) Cooking produces heat, smoke, steam and odours that must be removed quickly
  • (c) Kitchens have no windows
  • (d) Bedrooms have no fans

Answer: (b) Cooking produces heat, smoke, steam and odours that must be removed quickly — rooms with heat and moisture sources need a higher air-change rate.

Q10. What happens if a ceiling fan is mounted too close to the ceiling?

  • (a) It runs faster
  • (b) Airflow is restricted because the blades cannot draw in enough air from above
  • (c) It uses less electricity
  • (d) It becomes quieter

Answer: (b) Airflow is restricted because the blades cannot draw in enough air from above — a fan needs space above the blades to pull air down; a longer downrod fixes this on high ceilings.