Fan MCQs — Set 4
10 practice questions on fan airflow — CFM, room volume and air changes per hour — with worked answers and explanations.
Q1. What does CFM stand for when rating a fan?
- (a) Cubic feet per minute
- (b) Current flow per metre
- (c) Capacitor frequency per minute
- (d) Cooling factor per metre
Answer: (a) Cubic feet per minute — CFM measures how much air a fan moves each minute; a higher CFM means more airflow.
Q2. What is the formula for the CFM needed to ventilate a room?
- (a) CFM = room volume × air changes per hour ÷ 60
- (b) CFM = room area × 60 ÷ air changes per hour
- (c) CFM = room volume + air changes per hour
- (d) CFM = room area × ceiling height × 60
Answer: (a) CFM = room volume × air changes per hour ÷ 60 — volume in cubic feet times the air changes per hour, divided by 60 minutes, gives cubic feet per minute.
Q3. A room is 100 sq ft with a 10 ft ceiling and needs 6 air changes per hour. What CFM is required?
- (a) 60 CFM
- (b) 100 CFM
- (c) 600 CFM
- (d) 1,000 CFM
Answer: (b) 100 CFM — volume = 100 × 10 = 1,000 cu ft; 1,000 × 6 = 6,000 cu ft per hour; 6,000 ÷ 60 = 100 CFM.
Q4. A room is 150 sq ft with a 10 ft ceiling and needs 6 air changes per hour. What CFM is required?
- (a) 90 CFM
- (b) 120 CFM
- (c) 150 CFM
- (d) 250 CFM
Answer: (c) 150 CFM — volume = 150 × 10 = 1,500 cu ft; 1,500 × 6 = 9,000 cu ft per hour; 9,000 ÷ 60 = 150 CFM.
Q5. A room is 200 sq ft with a 10 ft ceiling and needs 6 air changes per hour. What CFM is required?
- (a) 120 CFM
- (b) 200 CFM
- (c) 300 CFM
- (d) 1,200 CFM
Answer: (b) 200 CFM — volume = 200 × 10 = 2,000 cu ft; 2,000 × 6 = 12,000 cu ft per hour; 12,000 ÷ 60 = 200 CFM.
Q6. If the ceiling height of a room doubles while the floor area and air changes per hour stay the same, what happens to the required CFM?
- (a) It stays the same
- (b) It doubles
- (c) It halves
- (d) It quadruples
Answer: (b) It doubles — doubling the height doubles the room volume, and CFM is proportional to volume.
Q7. What does a higher CFM rating on an exhaust fan mean in practice?
- (a) The fan uses less electricity
- (b) The fan moves more air and clears smoke or steam faster
- (c) The fan is quieter
- (d) The fan lasts longer
Answer: (b) The fan moves more air and clears smoke or steam faster — CFM is the airflow rate, so a higher CFM clears a room more quickly.
Q8. A bathroom is 50 sq ft. Using the rule of thumb of 1 CFM per sq ft, what size exhaust fan is needed?
- (a) 25 CFM
- (b) 50 CFM
- (c) 100 CFM
- (d) 500 CFM
Answer: (b) 50 CFM — 50 sq ft × 1 CFM per sq ft = 50 CFM, enough to clear steam and moisture from the bathroom.
Q9. Why does a kitchen need more air changes per hour than a bedroom?
- (a) Kitchens are always larger
- (b) Cooking produces heat, smoke, steam and odours that must be removed quickly
- (c) Kitchens have no windows
- (d) Bedrooms have no fans
Answer: (b) Cooking produces heat, smoke, steam and odours that must be removed quickly — rooms with heat and moisture sources need a higher air-change rate.
Q10. What happens if a ceiling fan is mounted too close to the ceiling?
- (a) It runs faster
- (b) Airflow is restricted because the blades cannot draw in enough air from above
- (c) It uses less electricity
- (d) It becomes quieter
Answer: (b) Airflow is restricted because the blades cannot draw in enough air from above — a fan needs space above the blades to pull air down; a longer downrod fixes this on high ceilings.
Also read: Power and Energy MCQs | All MCQ Topics