Q1. Where is a domestic energy meter normally installed?
- (a) After the last socket in the house
- (b) At the service entrance, after the main switch and before the distribution board
- (c) Inside the largest appliance
- (d) On the roof next to the solar panels
Answer: (b) At the service entrance, after the main switch and before the distribution board — it must measure all energy entering the premises.
Q2. A quick field check: a 1 kW load runs for 1 hour through a correct meter. What should the meter record?
- (a) 0.1 kWh
- (b) 1 kWh
- (c) 10 kWh
- (d) 1,000 kWh
Answer: (b) 1 kWh — 1 kW × 1 h = 1 kWh, so the register should advance by exactly 1 unit.
Q3. A 500 W appliance runs for 2 hours. How much energy is consumed?
- (a) 0.1 kWh
- (b) 1 kWh
- (c) 10 kWh
- (d) 250 kWh
Answer: (b) 1 kWh — 500 W × 2 h = 1,000 Wh = 1 kWh.
Q4. A load draws 10 A at 230 V for 4 hours. How much energy is recorded?
- (a) 2.3 kWh
- (b) 9.2 kWh
- (c) 23 kWh
- (d) 0.92 kWh
Answer: (b) 9.2 kWh — power = 230 × 10 = 2,300 W = 2.3 kW, and 2.3 kW × 4 h = 9.2 kWh.
Q5. A circuit rated 20 A at 120 V is loaded to the NEC 80% continuous limit and runs for 5 hours. How much energy is used?
- (a) 1.92 kWh
- (b) 9.6 kWh
- (c) 12 kWh
- (d) 2.4 kWh
Answer: (b) 9.6 kWh — the 80% limit is 20 × 120 × 0.8 = 1,920 W, and 1,920 W × 5 h = 9,600 Wh = 9.6 kWh.
Q6. A 1,500 W heater runs for 2 hours. How much energy does it consume?
- (a) 0.75 kWh
- (b) 3 kWh
- (c) 30 kWh
- (d) 750 kWh
Answer: (b) 3 kWh — 1,500 W × 2 h = 3,000 Wh = 3 kWh.
Q7. What is the difference between kW and kWh?
- (a) There is no difference
- (b) kW is power (rate of energy use); kWh is energy (power used over time)
- (c) kW is energy and kWh is power
- (d) kW is used for DC and kWh for AC only
Answer: (b) kW is power (rate of energy use); kWh is energy (power used over time) — a 2 kW heater running for 3 hours uses 6 kWh.
Q8. A meter constant is 600 rev/kWh and the disc makes 180 revolutions. How much energy is recorded?
- (a) 0.3 kWh
- (b) 3 kWh
- (c) 0.03 kWh
- (d) 1.08 kWh
Answer: (a) 0.3 kWh — energy = 180 ÷ 600 = 0.3 kWh.
Q9. A 3 kW load runs for 30 minutes. How much energy is consumed?
- (a) 0.15 kWh
- (b) 1.5 kWh
- (c) 6 kWh
- (d) 90 kWh
Answer: (b) 1.5 kWh — 30 minutes = 0.5 h, so 3 kW × 0.5 h = 1.5 kWh.
Q10. Which standard family covers accuracy and testing requirements for static (electronic) energy meters?
- (a) IEC 62053 series
- (b) IEC 60076 series
- (c) IEEE 1547 only
- (d) ISO 9000 only
Answer: (a) IEC 62053 series — IEC 62053 (with IEC 62052 for general requirements) specifies accuracy classes and tests for static watt-hour meters.