Energy Meter MCQs — Set 4

Electronic (static) energy meters: how they sense voltage and current, what they display, and why they beat the old disc meter.

Q1. What is the main difference between an electronic energy meter and an induction-type meter?

  • (a) The electronic meter has a heavier disc
  • (b) The electronic meter has no rotating disc; it uses sensors and a microprocessor
  • (c) The electronic meter needs no supply connection
  • (d) The electronic meter measures only DC

Answer: (b) The electronic meter has no rotating disc; it uses sensors and a microprocessor — voltage and current are sampled electronically and energy is calculated digitally.

Q2. In a static energy meter, the instantaneous power is calculated from:

  • (a) The speed of a rotating disc
  • (b) Sampled voltage and current values multiplied together
  • (c) The temperature of the meter case
  • (d) The resistance of the load

Answer: (b) Sampled voltage and current values multiplied together — an analogue-to-digital converter samples V and I many times per second and the processor multiplies them.

Q3. What does an electronic energy meter usually use to show the reading?

  • (a) A cyclometer dial only
  • (b) An LCD display
  • (c) A moving-coil needle
  • (d) A set of coloured LEDs for units

Answer: (b) An LCD display — it can cycle through kWh, voltage, current, power factor and maximum demand on the same screen.

Q4. Which advantage does a static meter have over an induction meter?

  • (a) It works without any power supply
  • (b) It has no friction error, no creeping, and higher accuracy at low loads
  • (c) It is always cheaper to manufacture
  • (d) It measures only active power and nothing else

Answer: (b) It has no friction error, no creeping, and higher accuracy at low loads — with no moving parts there is no bearing friction and no disc to creep.

Q5. “Maximum demand” (MD) shown by an electronic meter is:

  • (a) The highest voltage recorded in a month
  • (b) The highest average load (kW or kVA) over a fixed interval, usually 15 or 30 minutes
  • (c) The total energy used in a year
  • (d) The starting current of the largest motor

Answer: (b) The highest average load (kW or kVA) over a fixed interval, usually 15 or 30 minutes — utilities use MD for demand-based billing of commercial consumers.

Q6. Which feature of a static meter helps detect tampering?

  • (a) A heavier aluminium disc
  • (b) Event logging that records cover opening, reverse current and magnetic interference
  • (c) A louder humming sound
  • (d) A larger terminal box

Answer: (b) Event logging that records cover opening, reverse current and magnetic interference — the meter stores tamper events with date and time in non-volatile memory.

Q7. Why does an electronic meter keep its reading during a power cut?

  • (a) The disc keeps spinning on inertia
  • (b) Readings are stored in non-volatile memory
  • (c) A small battery drives the disc
  • (d) The utility re-sends the reading

Answer: (b) Readings are stored in non-volatile memory — the data is retained without power, so nothing is lost during an outage.

Q8. An electronic meter can measure power factor because it:

  • (a) Has a separate power-factor dial
  • (b) Samples voltage and current waveforms and compares their phase difference
  • (c) Weighs the load connected to it
  • (d) Counts the disc revolutions twice

Answer: (b) Samples voltage and current waveforms and compares their phase difference — the processor derives active, reactive and apparent power from the same samples.

Q9. What does the blinking LED on a static energy meter usually indicate?

  • (a) A fault in the meter
  • (b) Energy consumption — each pulse represents a fixed amount of energy (e.g. 3,200 imp/kWh)
  • (c) That the meter battery is dead
  • (d) That the meter is disconnected

Answer: (b) Energy consumption — each pulse represents a fixed amount of energy (e.g. 3,200 imp/kWh) — the pulse rate increases with load, just like disc speed in an old meter.

Q10. Which of these can a modern electronic meter record that an old induction meter cannot?

  • (a) Only the total kWh
  • (b) Time-of-use energy, voltage, current, power factor and tamper events
  • (c) Only the current in amperes
  • (d) Only the supply frequency

Answer: (b) Time-of-use energy, voltage, current, power factor and tamper events — the processor logs many parameters that a mechanical register cannot.

Also read: Home Load Calculator | All MCQ Topics