Distribution Board MCQs — Set 8
10 practice questions on IP ratings and where a distribution board should be installed, with answers and explanations.
Q1. What does IP stand for in an IP rating such as IP65?
- (a) Internal Power
- (b) Ingress Protection
- (c) Insulation Performance
- (d) Installation Position
Answer: (b) Ingress Protection — the IP code rates how well an enclosure keeps out solids and water.
Q2. An outdoor distribution board is rated IP65. What does this rating mean?
- (a) It is dust-tight and protected against water jets
- (b) It can be submerged in water permanently
- (c) It is protected against fingers only
- (d) It has no protection at all
Answer: (a) It is dust-tight and protected against water jets — the 6 means dust-tight and the 5 means protected against low-pressure water jets from any direction.
Q3. Which IP rating is most suitable for a distribution board installed outdoors in the rain?
- (a) IP20
- (b) IP65
- (c) IP00
- (d) IP10
Answer: (b) IP65 — an outdoor board needs protection against dust and rain, and IP65 provides both; IP20 offers no water protection.
Q4. What does the first digit of an IP rating describe?
- (a) Protection against water
- (b) Protection against solids such as dust and fingers
- (c) The voltage rating
- (d) The number of circuits
Answer: (b) Protection against solids such as dust and fingers — the first digit runs from 0 (no protection) to 6 (dust-tight).
Q5. What does the second digit of an IP rating describe?
- (a) Protection against water
- (b) Protection against dust
- (c) The current rating
- (d) The size of the enclosure
Answer: (a) Protection against water — the second digit runs from 0 (no protection) to 8 (continuous immersion), describing resistance to dripping, splashing, jets and immersion.
Q6. Why should a distribution board not be installed in the wet zones of a bathroom?
- (a) Because it would be too easy to reach
- (b) Because water and live electrical equipment together create a serious shock risk
- (c) Because the board would be too cold
- (d) Because the light would be too bright
Answer: (b) Because water and live electrical equipment together create a serious shock risk — wiring rules keep boards out of bathroom zones where splashing and steam are present.
Q7. At what kind of position should a distribution board be mounted?
- (a) High on a wall where no one can reach it
- (b) At an accessible height, easy to reach for switching off in an emergency
- (c) On the floor under a carpet
- (d) Inside a locked cupboard with no key available
Answer: (b) At an accessible height, easy to reach for switching off in an emergency — the board must be reachable so the supply can be cut quickly and the MCBs operated safely.
Q8. What does an IP20 rating mean for a distribution board?
- (a) It is waterproof
- (b) It is protected against fingers touching live parts, but has no water protection
- (c) It is dust-tight and waterproof
- (d) It can be used underwater
Answer: (b) It is protected against fingers touching live parts, but has no water protection — IP20 is the normal rating for an indoor board in a dry room.
Q9. A distribution board is to be fitted in a dusty workshop. What should be chosen?
- (a) An open board with no cover
- (b) An enclosed board with a higher IP rating suited to dust
- (c) A board with fewer MCBs
- (d) A board mounted at floor level
Answer: (b) An enclosed board with a higher IP rating suited to dust — dust can build up on live parts and cause tracking or overheating, so a sealed, dust-resistant enclosure is needed.
Q10. Why must a distribution board always have its cover or door fitted?
- (a) To keep the board warm
- (b) To prevent accidental contact with live parts inside
- (c) To hide the labels
- (d) To make the board heavier
Answer: (b) To prevent accidental contact with live parts inside — the cover is a safety barrier; a board left open exposes busbars and terminals that can give a fatal shock.
Also read: Electrical Safety MCQs | All MCQ Topics