Distribution Board MCQs — Set 2

10 practice questions on the main switch and isolator in a distribution board, with answers and explanations.

Q1. What is the job of the main switch in a distribution board?

  • (a) To trip on overload
  • (b) To isolate the whole board from the supply
  • (c) To detect earth leakage
  • (d) To measure energy consumption

Answer: (b) To isolate the whole board from the supply — the main switch cuts power to every outgoing circuit at once for maintenance or emergencies.

Q2. How does an isolator differ from an MCB?

  • (a) An isolator trips faster than an MCB
  • (b) An isolator has no overcurrent protection; it only switches the supply on and off
  • (c) An isolator can only be used on DC circuits
  • (d) An isolator always has a higher rating than an MCB

Answer: (b) An isolator has no overcurrent protection; it only switches the supply on and off — an MCB trips automatically on overload or short circuit, while an isolator must be operated by hand.

Q3. Can the main switch be relied on to clear a short-circuit fault?

  • (a) Yes, it trips instantly on a short circuit
  • (b) No, it is not a protective device and will not trip on its own
  • (c) Yes, but only on single-phase boards
  • (d) No, because it only works when the board is empty

Answer: (b) No, it is not a protective device and will not trip on its own — fault clearance is the job of the MCBs and fuses; the main switch only provides manual isolation.

Q4. What does a 100 A rating on a main switch mean?

  • (a) It trips when the current reaches 100 A
  • (b) It can carry up to 100 A continuously without damage
  • (c) It supplies exactly 100 A to every circuit
  • (d) It limits the supply voltage to 100 V

Answer: (b) It can carry up to 100 A continuously without damage — the rating is a current-carrying capacity, not a tripping value; a switch does not trip.

Q5. Where is the main switch connected inside a distribution board?

  • (a) Between the supply and the busbar
  • (b) Between the busbar and the earth bar
  • (c) After the last outgoing MCB
  • (d) Across the neutral and earth bars

Answer: (a) Between the supply and the busbar — incoming power passes through the main switch first, then to the busbar that feeds all the outgoing MCBs.

Q6. What is a double-pole (DP) main switch?

  • (a) A switch that controls two separate buildings
  • (b) A switch that breaks both the live and the neutral conductors
  • (c) A switch with two fuses inside it
  • (d) A switch rated for double the normal voltage

Answer: (b) A switch that breaks both the live and the neutral conductors — a DP switch isolates both poles, so the board is fully disconnected from the supply.

Q7. Why must the main switch be easily accessible at all times?

  • (a) So it can be switched off quickly in an emergency
  • (b) So children can practise using it
  • (c) So it stays cool
  • (d) So the meter reader can use it

Answer: (a) So it can be switched off quickly in an emergency — in a fire or shock incident, anyone must be able to cut the power without hunting for the board.

Q8. What happens when the main switch of a distribution board is switched off?

  • (a) Only the lighting circuits lose power
  • (b) All outgoing circuits lose power
  • (c) Only the socket circuits lose power
  • (d) Nothing changes until an MCB also trips

Answer: (b) All outgoing circuits lose power — the main switch feeds the busbar, so switching it off de-energises every circuit in the board.

Q9. Main switch or MCB — which one trips automatically on overload?

  • (a) The main switch
  • (b) The MCB
  • (c) Both trip at the same time
  • (d) Neither trips on overload

Answer: (b) The MCB — the MCB has a thermal-magnetic trip mechanism that opens on overload or short circuit; the main switch has none.

Q10. In a split-load distribution board, how is the main switch arranged?

  • (a) It feeds two sections, one of which is protected by an RCCB
  • (b) It is replaced by two energy meters
  • (c) It only feeds the lighting circuits
  • (d) It is fitted after the outgoing MCBs

Answer: (a) It feeds two sections, one of which is protected by an RCCB — in a split-load board some circuits are fed directly from the main switch and others through an RCCB, so a leakage trip does not black out the whole board.