Q1. Which conditions must be met before connecting a DC generator in parallel with a busbar?

  • (a) Same speed and same size only
  • (b) Same terminal voltage and same polarity as the busbar
  • (c) Same prime mover type only
  • (d) Same field resistance only

Answer: (b) Same terminal voltage and same polarity as the busbar — a voltage or polarity mismatch would drive a large circulating current.

Q2. Why is an equalizer connection used when compound generators run in parallel?

  • (a) To increase the speed of all generators
  • (b) To prevent one machine’s series field from taking the whole load and reversing the other
  • (c) To reduce the field current
  • (d) To connect the prime movers together

Answer: (b) To prevent one machine’s series field from taking the whole load and reversing the other — the equalizer joins the series fields so load is shared stably.

Q3. When two DC generators run in parallel, how is the load shared between them adjusted?

  • (a) By changing the prime mover speed only
  • (b) By adjusting the field excitation of each generator
  • (c) By changing the load resistance
  • (d) By swapping the brushes

Answer: (b) By adjusting the field excitation of each generator — raising a machine’s excitation raises its EMF, so it takes a larger share of the load.

Q4. What causes a circulating current between two DC generators running in parallel?

  • (a) Equal EMFs
  • (b) Unequal generated EMFs
  • (c) Equal field currents
  • (d) The same terminal voltage

Answer: (b) Unequal generated EMFs — the difference in EMF drives a current that circulates between the machines even with no external load.

Q5. DC generators are still used today for which of these applications?

  • (a) High-voltage AC transmission
  • (b) Electroplating, battery charging and arc welding
  • (c) Domestic ceiling fans
  • (d) Radio transmission

Answer: (b) Electroplating, battery charging and arc welding — these need smooth DC, which a DC generator supplies directly.

Q6. What is a main advantage of running two DC generators in parallel instead of one large one?

  • (a) Higher maximum voltage
  • (b) Better reliability and efficient operation at light loads
  • (c) No need for a prime mover
  • (d) Lower total cost in every case

Answer: (b) Better reliability and efficient operation at light loads — one machine can be shut down at light load, and a fault in one does not stop the supply.

Q7. If the generated EMF of one parallel generator falls below the busbar voltage, that machine will:

  • (a) Take more load
  • (b) Start acting as a motor and draw current from the busbar
  • (c) Increase its speed
  • (d) Produce AC output

Answer: (b) Start acting as a motor and draw current from the busbar — current reverses through the armature, so the generator motors instead of generating.

Q8. If one of two parallel generators has a higher EMF than the other, it will:

  • (a) Take a smaller share of the load
  • (b) Take a larger share of the load
  • (c) Stop running
  • (d) Reverse its polarity

Answer: (b) Take a larger share of the load — the machine with the higher EMF pushes more current into the common busbar.

Q9. Which of these is a common prime mover for a DC generator?

  • (a) A diesel engine
  • (b) A ceiling fan
  • (c) A transformer
  • (d) A rectifier

Answer: (a) A diesel engine — prime movers such as diesel engines, steam turbines or water turbines rotate the armature.

Q10. A DC generator delivers 8 A at a terminal voltage of 250 V. What is its output power?

  • (a) 2,000 W
  • (b) 31.25 W
  • (c) 200 W
  • (d) 20,000 W

Answer: (a) 2,000 W — P = V × I = 250 × 8 = 2,000 W.