DC Generator MCQs — Set 5

10 practice questions on compound DC generators — cumulative and differential types, long and short shunt.

Q1. In a cumulative compound DC generator, the series field flux:

  • (a) Opposes the shunt field flux
  • (b) Aids the shunt field flux
  • (c) Cancels the shunt field completely
  • (d) Has no effect on the shunt flux

Answer: (b) Aids the shunt field flux — the two fluxes add, so the total flux and voltage rise with load.

Q2. In a differential compound DC generator, the series field flux:

  • (a) Aids the shunt field flux
  • (b) Opposes the shunt field flux
  • (c) Is zero at all loads
  • (d) Reverses the armature current

Answer: (b) Opposes the shunt field flux — the net flux falls with load, so the terminal voltage drops rapidly.

Q3. A level-compounded (flat-compounded) generator is one in which:

  • (a) The terminal voltage rises sharply with load
  • (b) The terminal voltage stays nearly constant from no load to full load
  • (c) The terminal voltage falls to zero at full load
  • (d) The output is AC

Answer: (b) The terminal voltage stays nearly constant from no load to full load — the series field boost just cancels the IaRa drop and armature reaction.

Q4. An over-compounded DC generator is one in which:

  • (a) The terminal voltage at full load is higher than at no load
  • (b) The terminal voltage at full load is lower than at no load
  • (c) The series field is disconnected
  • (d) The shunt field is disconnected

Answer: (a) The terminal voltage at full load is higher than at no load — the series field over-compensates, useful for feeders with voltage drop along the line.

Q5. Compound DC generators are commonly used for:

  • (a) Loads that vary widely, such as traction and lighting with long feeders
  • (b) Constant-speed fans only
  • (c) Arc lamps only
  • (d) High-voltage AC transmission

Answer: (a) Loads that vary widely, such as traction and lighting with long feeders — the compound characteristic holds voltage steady despite changing load.

Q6. In a long-shunt compound generator, the shunt field winding is connected across:

  • (a) The armature only
  • (b) The series field only
  • (c) Both the armature and the series field together
  • (d) The load only

Answer: (c) Both the armature and the series field together — the shunt field sees the full terminal voltage.

Q7. In a short-shunt compound generator, the shunt field winding is connected across:

  • (a) Both the armature and the series field together
  • (b) The armature only
  • (c) The series field only
  • (d) An external battery

Answer: (b) The armature only — the shunt field is in parallel with the armature, and the series field is outside that parallel combination.

Q8. A compound generator produces a generated EMF of 230 V. Its armature current is 10 A and armature resistance is 2 Ω. What is the terminal voltage (ignoring brush drop and series field drop)?

  • (a) 210 V
  • (b) 250 V
  • (c) 230 V
  • (d) 200 V

Answer: (a) 210 V — V = Eg − IaRa = 230 − (10 × 2) = 230 − 20 = 210 V.

Q9. Why is a differential compound generator rarely used in practice?

  • (a) It is too efficient
  • (b) Its voltage falls rapidly with load and it can become unstable
  • (c) It has no commutator
  • (d) It cannot run at no load

Answer: (b) Its voltage falls rapidly with load and it can become unstable — the opposing series flux can weaken the net flux so much that the machine may even reverse.

Q10. A compound generator combines the advantages of shunt and series machines because:

  • (a) The shunt field gives steady voltage while the series field boosts voltage as load rises
  • (b) It has two commutators
  • (c) It needs no prime mover
  • (d) It produces both AC and DC

Answer: (a) The shunt field gives steady voltage while the series field boosts voltage as load rises — together they keep terminal voltage nearly constant over the load range.

Also read: Dynamo vs Alternator | All MCQ Topics