DC Generator MCQs — Set 1

10 practice questions on DC generator basics and the EMF equation, with answers and worked explanations.

Q1. A 4-pole lap-wound DC generator has a flux per pole of 0.02 Wb, runs at 1500 rpm and has 200 armature conductors. What is the generated EMF?

  • (a) 50 V
  • (b) 100 V
  • (c) 200 V
  • (d) 400 V

Answer: (b) 100 V — Eg = P × Φ × N × Z ÷ (60 × A) = 4 × 0.02 × 1500 × 200 ÷ (60 × 4) = 24,000 ÷ 240 = 100 V.

Q2. A DC generator converts which form of energy into which?

  • (a) Electrical energy into mechanical energy
  • (b) Mechanical energy into electrical energy
  • (c) Heat energy into mechanical energy
  • (d) Chemical energy into electrical energy

Answer: (b) Mechanical energy into electrical energy — the prime mover rotates the armature in a magnetic field and EMF is induced.

Q3. Which rule gives the direction of the induced EMF in a DC generator?

  • (a) Fleming’s left-hand rule
  • (b) Fleming’s right-hand rule
  • (c) Lenz’s law only
  • (d) Right-hand grip rule

Answer: (b) Fleming’s right-hand rule — thumb = motion, first finger = field, second finger = induced EMF direction.

Q4. The speed of a DC generator is doubled while the flux per pole stays the same. What happens to the generated EMF?

  • (a) It halves
  • (b) It stays the same
  • (c) It doubles
  • (d) It quadruples

Answer: (c) It doubles — generated EMF is directly proportional to speed (Eg ∝ N).

Q5. A 2-pole wave-wound DC generator has a flux per pole of 0.05 Wb, runs at 1200 rpm and has 100 armature conductors. What is the generated EMF?

  • (a) 50 V
  • (b) 100 V
  • (c) 150 V
  • (d) 200 V

Answer: (b) 100 V — Eg = 2 × 0.05 × 1200 × 100 ÷ (60 × 2) = 12,000 ÷ 120 = 100 V.

Q6. A DC generator produces a generated EMF of 250 V. Its armature current is 20 A and armature resistance is 0.5 Ω. What is the terminal voltage (ignoring brush drop)?

  • (a) 230 V
  • (b) 240 V
  • (c) 250 V
  • (d) 260 V

Answer: (b) 240 V — V = Eg − IaRa = 250 − (20 × 0.5) = 250 − 10 = 240 V.

Q7. In a simplex lap winding, the number of parallel paths in the armature is equal to:

  • (a) 2
  • (b) The number of poles
  • (c) The number of commutator segments
  • (d) Half the number of poles

Answer: (b) The number of poles — for lap winding A = P, which is why it suits high-current, low-voltage generators.

Q8. If the flux per pole of a DC generator is increased while speed stays constant, the generated EMF:

  • (a) Decreases
  • (b) Stays the same
  • (c) Increases
  • (d) Becomes zero

Answer: (c) Increases — generated EMF is directly proportional to flux per pole (Eg ∝ Φ).

Q9. A DC generator delivers 10 A at a terminal voltage of 230 V. What is its output power?

  • (a) 230 W
  • (b) 2,300 W
  • (c) 23,000 W
  • (d) 23 W

Answer: (b) 2,300 W — P = V × I = 230 × 10 = 2,300 W.

Q10. In a simplex wave winding, the number of parallel paths in the armature is always:

  • (a) Equal to the number of poles
  • (b) 2
  • (c) Equal to the number of brushes
  • (d) Equal to the number of coils

Answer: (b) 2 — wave winding always has 2 parallel paths regardless of pole count, suiting high-voltage, low-current generators.