Compressor MCQs — Set 9

10 practice questions on compressor tripping, overheating, leaks and noise faults, with answers and explanations.

Q1. The circuit breaker trips every time the compressor tries to start. What is the most likely cause?

  • (a) The receiver is full of air
  • (b) High starting current, a faulty start capacitor, or a shorted motor winding
  • (c) A clean intake filter
  • (d) The oil level is correct

Answer: (b) High starting current, a faulty start capacitor, or a shorted motor winding — check the capacitor and the motor before fitting a bigger breaker.

Q2. Which of these can make a compressor overheat?

  • (a) Low oil level, a clogged intake filter, blocked ventilation or high ambient temperature
  • (b) A freshly drained receiver
  • (c) A new drive belt
  • (d) A low cut-out pressure

Answer: (a) Low oil level, a clogged intake filter, blocked ventilation or high ambient temperature — overheating is usually a cooling or lubrication problem, not an electrical one.

Q3. A compressor starts and stops every few seconds. What is this called, and what can cause it?

  • (a) Short-cycling, caused by a pressure-switch differential set too small, a receiver that is too small, or a leak
  • (b) Normal running
  • (c) Overloading, caused by too much oil
  • (d) Freezing, caused by cold air

Answer: (a) Short-cycling, caused by a pressure-switch differential set too small, a receiver that is too small, or a leak — frequent starts overheat the motor.

Q4. A loud knocking noise comes from the pump while it runs. What is the likely cause?

  • (a) A full receiver tank
  • (b) Worn bearings or a loose piston pin
  • (c) Clean oil
  • (d) A tight belt

Answer: (b) Worn bearings or a loose piston pin — knocking from inside the pump means worn mechanical parts and the pump should be stopped and inspected.

Q5. Oil is found in the compressed-air discharge line. What is the most likely cause?

  • (a) The receiver is too large
  • (b) Worn piston rings or overfilled oil letting oil pass into the air
  • (c) A new air filter
  • (d) Low ambient temperature

Answer: (b) Worn piston rings or overfilled oil letting oil pass into the air — check the oil level first, then suspect worn rings.

Q6. A 30 mA RCCB trips when the compressor runs. What does this point to?

  • (a) High air pressure
  • (b) Earth leakage — an insulation fault letting current flow to earth
  • (c) A clogged air filter
  • (d) Low oil level

Answer: (b) Earth leakage — an insulation fault letting current flow to earth — the motor or wiring insulation must be tested before the compressor is used again.

Q7. The motor hums but the pump does not turn. What is the most likely cause?

  • (a) A failed start capacitor or a seized pump
  • (b) A full receiver
  • (c) A leaking drain valve
  • (d) A dirty air filter

Answer: (a) A failed start capacitor or a seized pump — the motor has power but cannot develop torque, or the pump is mechanically jammed.

Q8. How can small air leaks at fittings be found?

  • (a) By listening only
  • (b) By brushing soapy water on the joints — bubbles show where air escapes
  • (c) By raising the cut-out pressure
  • (d) By draining the receiver

Answer: (b) By brushing soapy water on the joints — bubbles show where air escapes — this finds leaks too small to hear.

Q9. The safety valve keeps lifting even though the receiver is not overfilled. What is the likely cause?

  • (a) The pressure switch has failed to stop the motor, or the cut-out is set too high
  • (b) The drain valve is open
  • (c) The intake filter is new
  • (d) The oil is fresh

Answer: (a) The pressure switch has failed to stop the motor, or the cut-out is set too high — the valve is doing its job; the control fault must be fixed.

Q10. A compressor vibrates excessively while running. What is the most likely cause?

  • (a) Loose mounting bolts or a worn, misaligned pulley
  • (b) A full receiver
  • (c) Clean oil
  • (d) A low cut-in pressure

Answer: (a) Loose mounting bolts or a worn, misaligned pulley — check the mountings, belt alignment and pulley condition first.

Also read: Electrical Safety MCQs | All MCQ Topics