Compressor MCQs — Set 6

10 practice questions on pressure switches, safety valves and compressor controls, with worked answers.

Q1. A pressure switch is set to cut in at 6 bar and cut out at 8 bar. What is the pressure differential?

  • (a) 1 bar
  • (b) 2 bar
  • (c) 6 bar
  • (d) 14 bar

Answer: (b) 2 bar — differential = cut-out minus cut-in = 8 − 6 = 2 bar.

Q2. A pressure switch cuts in at 4 bar and cuts out at 7 bar. What is the pressure differential?

  • (a) 2 bar
  • (b) 3 bar
  • (c) 4 bar
  • (d) 11 bar

Answer: (b) 3 bar — differential = cut-out minus cut-in = 7 − 4 = 3 bar.

Q3. A compressor cuts out at 8 bar. At what pressure should its safety valve be set?

  • (a) 6 bar
  • (b) 8 bar
  • (c) 10 bar
  • (d) 4 bar

Answer: (c) 10 bar — the safety valve must sit above the cut-out pressure so it does not blow in normal running, but below the vessel’s maximum rating.

Q4. What does the pressure switch on a compressor do?

  • (a) It drains water from the receiver
  • (b) It starts the motor when pressure falls to the cut-in setting and stops it at the cut-out setting
  • (c) It lubricates the pump
  • (d) It cools the discharge air

Answer: (b) It starts the motor when pressure falls to the cut-in setting and stops it at the cut-out setting — it keeps the receiver between the two set pressures.

Q5. What is the job of the unloader valve on a reciprocating compressor?

  • (a) To vent head pressure when the compressor stops, so the motor can restart without load
  • (b) To add oil to the cylinders
  • (c) To drain the receiver
  • (d) To filter the intake air

Answer: (a) To vent head pressure when the compressor stops, so the motor can restart without load — starting against trapped high-pressure air would overload the motor.

Q6. The contacts of a pressure switch weld closed. What happens?

  • (a) The compressor stops and never restarts
  • (b) The compressor keeps running, pressure rises, and the safety valve eventually lifts
  • (c) The receiver drains itself
  • (d) The motor runs backwards

Answer: (b) The compressor keeps running, pressure rises, and the safety valve eventually lifts — welded contacts cannot open at the cut-out pressure.

Q7. What is the risk of raising the cut-out pressure above the compressor’s design pressure?

  • (a) The compressor delivers cleaner air
  • (b) Overpressure, safety-valve operation and stress on the receiver and pipework
  • (c) The motor runs cooler
  • (d) The duty cycle improves

Answer: (b) Overpressure, safety-valve operation and stress on the receiver and pipework — the cut-out must stay within the rated pressure of the whole system.

Q8. What does the differential adjustment on a pressure switch control?

  • (a) The motor speed
  • (b) The gap between the cut-in and cut-out pressures
  • (c) The oil level
  • (d) The receiver size

Answer: (b) The gap between the cut-in and cut-out pressures — a wider differential means fewer starts and stops.

Q9. A compressor motor is rated 2 HP. How much power is that in watts?

  • (a) 746 W
  • (b) 1,492 W
  • (c) 2,000 W
  • (d) 1,000 W

Answer: (b) 1,492 W — 1 HP = 746 W, so 2 × 746 = 1,492 W.

Q10. What does the pressure gauge on the receiver show?

  • (a) The motor current
  • (b) The pressure of the stored air in the receiver
  • (c) The oil temperature
  • (d) The free air delivery

Answer: (b) The pressure of the stored air in the receiver — it tells the user how much pressure is available for the tools.

Also read: GFCI Outlet Keeps Tripping | All MCQ Topics