Circuit Breaker Types MCQs — Set 1
10 practice questions on MCB basics — what a miniature circuit breaker does, how it trips, and where it is used. Work each one out before checking the answer.
Q1. What is the main job of an MCB in a home distribution board?
- (a) To step voltage up or down
- (b) To protect the circuit from overload and short circuit
- (c) To measure the energy consumed
- (d) To store charge for later use
Answer: (b) To protect the circuit from overload and short circuit — an MCB automatically disconnects the supply when current exceeds its rating or a short circuit occurs.
Q2. What does MCB stand for?
- (a) Main Control Box
- (b) Miniature Circuit Breaker
- (c) Magnetic Current Breaker
- (d) Manual Cut-off Breaker
Answer: (b) Miniature Circuit Breaker — a compact, resettable breaker used mainly in homes and small commercial installations.
Q3. What is the biggest practical advantage of an MCB over a rewirable fuse?
- (a) It is cheaper to buy
- (b) It can be reset and reused after tripping
- (c) It works without any current flowing
- (d) It increases the supply voltage
Answer: (b) It can be reset and reused after tripping — a blown fuse wire must be replaced, while an MCB is simply switched back on once the fault is cleared.
Q4. What does the “20 A” marking on an MCB mean?
- (a) It trips instantly at exactly 20 A
- (b) 20 A is its rated current — the maximum current it can carry continuously without tripping
- (c) It can interrupt a fault of 20 kA
- (d) It needs 20 A to switch on
Answer: (b) 20 A is its rated current — the maximum current it can carry continuously without tripping. Small overloads trip it after a time delay, not instantly.
Q5. Which part inside an MCB trips it on a sustained overload?
- (a) A bimetallic strip that bends as it heats up
- (b) A vacuum bottle
- (c) A capacitor bank
- (d) A step-down transformer
Answer: (a) A bimetallic strip that bends as it heats up — the strip is heated by the load current (I²R) and bends to release the trip mechanism after a delay.
Q6. Which part inside an MCB trips it instantly on a short circuit?
- (a) The bimetallic strip
- (b) An electromagnetic solenoid coil
- (c) The arc chute spring
- (d) The test button
Answer: (b) An electromagnetic solenoid coil — the huge short-circuit current creates a strong magnetic pull that trips the breaker in milliseconds.
Q7. A single-pole (SP) MCB protects which conductor?
- (a) The neutral only
- (b) The earth wire only
- (c) One live (phase) conductor
- (d) Live, neutral and earth together
Answer: (c) One live (phase) conductor — an SP MCB switches and protects only the phase wire; the neutral passes through unswitched.
Q8. A lighting circuit in a home is typically protected by an MCB rated at:
- (a) 6 A
- (b) 32 A
- (c) 63 A
- (d) 100 A
Answer: (a) 6 A — lighting loads are small, so a 6 A (or 10 A) MCB is the usual choice, while socket circuits use 16 A or 20 A.
Q9. After an MCB trips, what is the correct first step before switching it back on?
- (a) Switch it on immediately, as many times as needed
- (b) Find and remove the cause of the overload or fault, then reset it
- (c) Replace the MCB with one of a higher rating
- (d) Short the terminals to test it
Answer: (b) Find and remove the cause of the overload or fault, then reset it — repeatedly resetting a breaker on a live fault can damage the breaker and the wiring.
Q10. General-purpose socket outlets in a home are commonly protected by an MCB rated at:
- (a) 6 A
- (b) 16 A
- (c) 100 A
- (d) 200 A
Answer: (b) 16 A — a 16 A MCB suits socket circuits, giving 16 × 230 = 3,680 W capacity, while lighting uses 6 A.
Also read: AFCI Breaker Keeps Tripping | All MCQ Topics