Charge Controller MCQs — Set 10
10 practice questions on charge controller faults and troubleshooting — finding why a system is not charging. Work each one out before checking the answer.
Q1. The charge controller display is completely blank. What should be checked first?
- (a) The solar panel angle
- (b) The battery connection and the fuse/breaker between battery and controller
- (c) The load timer setting
- (d) The panel’s colour
Answer: (b) The battery connection and the fuse/breaker between battery and controller — the controller is powered from the battery, so a dead display usually means no battery power reaching it.
Q2. Panel voltage is present at the controller input, but no charging current flows on a sunny day. What is a likely cause?
- (a) The battery is already full and the controller is in float
- (b) The panels are producing too much power
- (c) The load terminals are switched on
- (d) The battery is too large
Answer: (a) The battery is already full and the controller is in float — a full battery draws almost no current, so zero charging current on a full battery is normal, not a fault.
Q3. The battery voltage keeps falling day by day despite sunshine. What is the most likely system fault?
- (a) The controller is in float mode
- (b) The solar array or controller is undersized for the daily load
- (c) The battery is too new
- (d) The panels are too clean
Answer: (b) The solar array or controller is undersized for the daily load — if daily use exceeds daily harvest, the battery falls a little further behind every day.
Q4. The charge controller feels very hot and its output current keeps dropping. What is the likely cause?
- (a) The controller is undersized for the array, or it has poor ventilation
- (b) The battery is fully charged
- (c) It is night time
- (d) The panels are in shade
Answer: (a) The controller is undersized for the array, or it has poor ventilation — heat forces the controller to derate, so current falls; a bigger controller or better airflow fixes it.
Q5. The load connected to the load terminals does not work, but the battery voltage is healthy. What should be checked?
- (a) Whether the load output is switched off or an LVD/timer mode is active
- (b) The solar panel tilt angle
- (c) The battery water level
- (d) The inverter’s AC output
Answer: (a) Whether the load output is switched off or an LVD/timer mode is active — a healthy battery with a dead load usually means the load output itself is off, tripped or timed out.
Q6. The battery type setting is “flooded lead-acid” but the battery is actually lithium (LiFePO4). What is the risk?
- (a) No risk — all batteries charge the same way
- (b) The controller applies lead-acid voltages, float and possibly equalization, which can damage the lithium battery
- (c) The panels will produce less power
- (d) The load terminals will switch off
Answer: (b) The controller applies lead-acid voltages, float and possibly equalization, which can damage the lithium battery — the battery-type setting must always match the installed battery.
Q7. Charging is intermittent — current comes and goes on a clear sunny day. What is a common cause?
- (a) Loose or corroded terminals causing a voltage drop and intermittent contact
- (b) The battery is too big
- (c) The controller is too efficient
- (d) The panels face south
Answer: (a) Loose or corroded terminals causing a voltage drop and intermittent contact — bad connections are one of the most common causes of intermittent charging.
Q8. The controller shows a fault or blinking error light. What is the correct first step?
- (a) Ignore it — error lights are decorative
- (b) Disconnect the battery immediately
- (c) Read the error code in the controller manual and check the indicated fault
- (d) Replace the solar panels
Answer: (c) Read the error code in the controller manual and check the indicated fault — the code names the problem (overvoltage, over-temperature, short circuit) and guessing wastes time.
Q9. Part of the array is shaded for part of the day and the MPPT controller’s output drops sharply. Why?
- (a) Shade on one panel drags down the string’s power and the MPPT hunts for a new, lower power point
- (b) The controller switches to PWM mode in shade
- (c) The battery disconnects in shade
- (d) The panels stop producing voltage entirely
Answer: (a) Shade on one panel drags down the string’s power and the MPPT hunts for a new, lower power point — shading is an array problem, not a controller fault, and is fixed by re-siting or re-wiring the panels.
Q10. A home uses 30 kWh per day and the site gets 5 peak sun hours. How many 400 W panels are needed to cover the daily use?
- (a) 8 panels
- (b) 10 panels
- (c) 15 panels
- (d) 30 panels
Answer: (c) 15 panels — array size = 30 kWh ÷ 5 h = 6 kW; 6,000 ÷ 400 = 15 panels.