Q1. What does reverse-polarity protection in a charge controller do?
- (a) It increases the charging voltage
- (b) It protects the controller if the battery or panel wires are connected the wrong way round
- (c) It reverses the current every night
- (d) It swaps the load and battery terminals
Answer: (b) It protects the controller if the battery or panel wires are connected the wrong way round — without it, reversed wires can destroy the controller instantly.
Q2. A short circuit occurs on the load terminals. What should the controller do?
- (a) Keep supplying full current
- (b) Cut off the load output to protect itself and the wiring
- (c) Disconnect the solar panels permanently
- (d) Raise the battery voltage
Answer: (b) Cut off the load output to protect itself and the wiring — most controllers have electronic short-circuit protection on the load output.
Q3. What happens when a charge controller gets too hot?
- (a) It charges the battery faster
- (b) It reduces its output current (derates) or shuts down until it cools
- (c) It increases the panel voltage
- (d) Nothing — heat does not affect controllers
Answer: (b) It reduces its output current (derates) or shuts down until it cools — over-temperature protection prevents heat damage to the electronics.
Q4. At night, what stops the battery from discharging backwards through the solar panels?
- (a) The panels glow and block the current
- (b) The charge controller blocks reverse current flow from battery to panels
- (c) The battery disconnects itself
- (d) The inverter blocks it
Answer: (b) The charge controller blocks reverse current flow from battery to panels — without this, the battery would slowly drain into the panels overnight.
Q5. A battery temperature sensor reports that the battery is dangerously hot during charging. What should the controller do?
- (a) Keep charging at full current
- (b) Stop or reduce charging until the battery cools to a safe temperature
- (c) Disconnect the solar panels permanently
- (d) Raise the charging voltage
Answer: (b) Stop or reduce charging until the battery cools to a safe temperature — charging a hot battery, especially lithium, risks thermal runaway and permanent damage.
Q6. Where should a fuse or DC breaker be fitted in a solar charging system?
- (a) Only on the AC output of the inverter
- (b) Between the battery and the charge controller (and between controller and panels) to protect the wiring
- (c) Inside the solar panel frame
- (d) Nowhere — the controller makes fuses unnecessary
Answer: (b) Between the battery and the charge controller (and between controller and panels) to protect the wiring — the controller’s internal protection does not replace fuses on the battery cables.
Q7. Deep-discharge protection in a charge controller works by:
- (a) Adding charge to a flat battery
- (b) Disconnecting the load at low battery voltage (LVD) so the battery is not drained further
- (c) Short-circuiting the panels
- (d) Raising the float voltage
Answer: (b) Disconnecting the load at low battery voltage (LVD) so the battery is not drained further — LVD is the controller’s deep-discharge protection.
Q8. What protects a charge controller and solar system from a nearby lightning surge?
- (a) The battery itself
- (b) A surge protection device (SPD) fitted on the DC side
- (c) The load terminals
- (d) A bigger solar array
Answer: (b) A surge protection device (SPD) fitted on the DC side — an SPD diverts surge voltage to earth before it reaches the controller.
Q9. A load drawing more than the controller’s load rating is connected to the load terminals. What is the likely result?
- (a) The overload protection trips and the load output switches off
- (b) The load runs at reduced brightness only
- (c) The battery voltage rises
- (d) The panels produce extra power
Answer: (a) The overload protection trips and the load output switches off — the controller protects its load circuit from currents above its rating.
Q10. Which combination gives a solar charging system the best protection?
- (a) A charge controller alone, with no fuses
- (b) The controller’s built-in protections plus correctly sized fuses/breakers and an SPD
- (c) A larger battery alone
- (d) Thicker panel frames alone
Answer: (b) The controller’s built-in protections plus correctly sized fuses/breakers and an SPD — internal protection and external protection cover different faults.