Q1. What are the load terminals on a charge controller for?
- (a) Connecting the solar panels
- (b) Powering DC loads, such as lights, directly from the battery through the controller
- (c) Connecting a second battery bank
- (d) Earthing the controller
Answer: (b) Powering DC loads, such as lights, directly from the battery through the controller — the controller can then switch the loads off to protect the battery.
Q2. What does LVD (low-voltage disconnect) do?
- (a) It disconnects the solar panels at noon
- (b) It disconnects the load when the battery voltage falls to a set low level, about 11.1 V on a 12 V battery
- (c) It disconnects the battery when it is fully charged
- (d) It increases the load current
Answer: (b) It disconnects the load when the battery voltage falls to a set low level, about 11.1 V on a 12 V battery — this stops the load draining the battery into deep discharge.
Q3. After an LVD trip, the load is reconnected when the battery recovers to the reconnect voltage (LVR), typically about:
- (a) 10.0 V
- (b) 11.1 V
- (c) 12.6 V
- (d) 14.4 V
Answer: (c) 12.6 V — the reconnect voltage is set higher than the disconnect voltage so the load does not switch on and off repeatedly.
Q4. In dusk-to-dawn mode, the controller’s load output is:
- (a) On during the day and off at night
- (b) Off during the day and on at night, for lights such as street lamps
- (c) On for exactly one hour after sunset
- (d) Always on, day and night
Answer: (b) Off during the day and on at night, for lights such as street lamps — the controller detects darkness from the panel voltage and switches the load on.
Q5. Why should an inverter NOT be connected to the load terminals of a charge controller?
- (a) The inverter would charge the battery too fast
- (b) An inverter’s surge current on start-up far exceeds the load terminals’ rating and can damage the controller
- (c) Inverters only work at night
- (d) The inverter would stop the panels working
Answer: (b) An inverter’s surge current on start-up far exceeds the load terminals’ rating and can damage the controller — inverters must be wired directly to the battery (with their own fuse).
Q6. The load terminals are rated at 20 A. A 12 V DC load drawing 30 A is connected to them. What happens?
- (a) The load runs normally at 30 A
- (b) The controller’s load protection trips or the terminals are damaged
- (c) The battery charges faster
- (d) The solar panels disconnect
Answer: (b) The controller’s load protection trips or the terminals are damaged — loads on the load terminals must stay within the controller’s load current rating.
Q7. Some charge controllers have a 5 V USB output. What is it for?
- (a) Charging the main battery bank
- (b) Powering or charging small 5 V devices, such as phones, directly from the system
- (c) Connecting the solar panels
- (d) Earthing the controller
Answer: (b) Powering or charging small 5 V devices, such as phones, directly from the system — the USB output is a low-power auxiliary output, separate from the main load terminals.
Q8. A street light is set to timer mode: 6 hours after sunset. What does the controller do?
- (a) It keeps the light on all night
- (b) It switches the load on at dusk and off 6 hours later
- (c) It switches the light on 6 hours before sunset
- (d) It dims the light every 6 hours
Answer: (b) It switches the load on at dusk and off 6 hours later — timer mode saves battery energy compared with running the light all night.
Q9. How do the load terminals differ from the battery terminals on a charge controller?
- (a) They are the same connection with two names
- (b) The load terminals are switched and protected by the controller; the battery terminals are a direct connection to the battery
- (c) The load terminals carry AC power
- (d) The load terminals charge the battery
Answer: (b) The load terminals are switched and protected by the controller; the battery terminals are a direct connection to the battery — the controller can cut the load off at LVD but never cuts the battery off.
Q10. A 12 V lead-acid battery at rest reads about 12.2 V. Roughly what state of charge is this?
- (a) 100% — fully charged
- (b) About 50% — half charged, and the load should soon be disconnected
- (c) 0% — completely flat
- (d) 90% — nearly full
Answer: (b) About 50% — half charged, and the load should soon be disconnected — a resting 12 V lead-acid battery reads about 12.7 V full and about 12.2 V at half charge.