Charge Controller MCQs — Set 6
10 practice questions on the charging stages — bulk, absorption, float and equalization — and what each stage does to the battery. Work each one out before checking the answer.
Q1. What is the correct order of the charging stages for a lead-acid battery?
- (a) Float → absorption → bulk
- (b) Bulk → absorption → float
- (c) Absorption → bulk → float
- (d) Equalization → bulk → float
Answer: (b) Bulk → absorption → float — bulk delivers maximum current, absorption holds constant voltage while current tapers, and float maintains the full battery.
Q2. In the bulk stage, the charge controller delivers:
- (a) Constant voltage with falling current
- (b) Maximum available current while the battery voltage rises
- (c) A tiny trickle current only
- (d) No current at all
Answer: (b) Maximum available current while the battery voltage rises — bulk is the fastest stage and continues until the battery reaches its absorption voltage.
Q3. During absorption, a 12 V lead-acid battery is typically held at about:
- (a) 12.0 V
- (b) 13.2 V
- (c) 14.4 V
- (d) 16.0 V
Answer: (c) 14.4 V — the controller holds the absorption voltage constant while the charging current gradually tapers off.
Q4. What is the purpose of the float stage?
- (a) To fast-charge a flat battery
- (b) To hold a full battery at about 13.6 V, replacing self-discharge without overcharging
- (c) To discharge the battery before the next day
- (d) To test the solar panels
Answer: (b) To hold a full battery at about 13.6 V, replacing self-discharge without overcharging — float is a low-voltage maintenance stage.
Q5. What is equalization charging?
- (a) Charging all batteries in the bank at different voltages
- (b) A controlled, deliberate overcharge (about 15.5 V on a 12 V flooded battery) that balances the cells and breaks down sulphation
- (c) Charging the battery with equal amounts of sun and wind power
- (d) Switching the controller off for an equal time each day
Answer: (b) A controlled, deliberate overcharge (about 15.5 V on a 12 V flooded battery) that balances the cells and breaks down sulphation — it is used occasionally on flooded lead-acid batteries only.
Q6. What happens if the absorption stage is cut too short every day?
- (a) The battery charges faster
- (b) The battery never fully charges, sulphation builds up and capacity falls
- (c) The float voltage rises
- (d) The panels produce more power
Answer: (b) The battery never fully charges, sulphation builds up and capacity falls — the last part of the charge happens slowly in absorption, and skipping it leaves the battery chronically undercharged.
Q7. Which battery type generally does NOT need float or equalization stages?
- (a) Flooded lead-acid
- (b) AGM lead-acid
- (c) Lithium (LiFePO4)
- (d) Gel lead-acid
Answer: (c) Lithium (LiFePO4) — lithium charges in bulk and absorption and then stops; holding it at float voltage and equalizing it can damage it, so the controller must be set to the lithium profile.
Q8. When does the bulk stage end?
- (a) When the sun sets
- (b) When the battery voltage reaches the absorption set-point, about 14.4 V for a 12 V battery
- (c) After exactly one hour
- (d) When the load terminals switch on
Answer: (b) When the battery voltage reaches the absorption set-point, about 14.4 V for a 12 V battery — the controller then switches from constant current to constant voltage.
Q9. A single-stage charger that only applies a fixed high voltage is a poor choice for a lead-acid battery because:
- (a) It charges too slowly
- (b) It keeps pushing full voltage after the battery is full, overcharging and drying it out
- (c) It cannot work in daylight
- (d) It needs a bigger solar array
Answer: (b) It keeps pushing full voltage after the battery is full, overcharging and drying it out — a multi-stage controller tapers the charge, which is what extends battery life.
Q10. During float, the charging current is:
- (a) At its maximum value
- (b) Very small — just enough to cover self-discharge and small loads
- (c) Equal to the panel’s short-circuit current
- (d) Reversed, discharging the battery
Answer: (b) Very small — just enough to cover self-discharge and small loads — the battery is already full, so only a trickle is needed.