Q1. What is a busbar in an electrical switchboard?
- (a) A flexible cable used for earthing
- (b) A rigid metal bar that distributes power to several circuits
- (c) A type of circuit breaker
- (d) An insulating cover for cables
Answer: (b) A rigid metal bar that distributes power to several circuits — a busbar is a common conductor inside a panel or switchboard from which many outgoing circuits are fed.
Q2. What is the main job of a busbar inside a distribution panel?
- (a) To step voltage up or down
- (b) To collect incoming power and distribute it to outgoing feeders
- (c) To measure the load current
- (d) To protect the panel against lightning
Answer: (b) To collect incoming power and distribute it to outgoing feeders — the incoming supply connects to the busbar, and each outgoing circuit taps off it.
Q3. How does a busbar differ from an ordinary cable?
- (a) A busbar is rigid and bare, while a cable is flexible and insulated
- (b) A busbar carries only DC current
- (c) A cable can carry more current than any busbar
- (d) A busbar is always buried underground
Answer: (a) A busbar is rigid and bare, while a cable is flexible and insulated — busbars are solid bars mounted on insulators inside an enclosure, whereas cables are flexible insulated conductors.
Q4. Which metal is most commonly used for busbars in switchgear?
- (a) Iron
- (b) Aluminium only
- (c) Copper
- (d) Lead
Answer: (c) Copper — copper is the usual choice because of its high conductivity, good mechanical strength and reliable joints.
Q5. What is the most common shape of busbar used in low-voltage panels?
- (a) Hollow tube
- (b) Round rod
- (c) Flat rectangular bar
- (d) Triangular bar
Answer: (c) Flat rectangular bar — flat bars are easy to joint, bolt and cool, so they dominate LV switchboards and panels.
Q6. A three-phase load draws 50 kW at 400 V with a power factor of 0.8. What current must the busbar carry?
- (a) 45.1 A
- (b) 62.5 A
- (c) 90.2 A
- (d) 125 A
Answer: (c) 90.2 A — I = P ÷ (√3 × V × pf) = 50,000 ÷ (1.732 × 400 × 0.8) = 50,000 ÷ 554 = 90.2 A.
Q7. In a three-phase busbar system, which colours are commonly used to identify the R, Y and B phases?
- (a) Red, yellow and blue
- (b) Green, white and black
- (c) Brown, grey and pink
- (d) Orange, violet and grey
Answer: (a) Red, yellow and blue — R, Y and B busbars are conventionally painted or sleeved red, yellow and blue for easy identification.
Q8. Why are busbars usually left bare instead of being insulated like cables?
- (a) Bare bars are cheaper to manufacture
- (b) Air around the bars plus support insulators give the needed insulation and cooling
- (c) Insulation would increase the current rating too much
- (d) Bare bars cannot develop faults
Answer: (b) Air around the bars plus support insulators give the needed insulation and cooling — the air gap and the insulators between bars provide insulation, while the bare surface sheds heat freely.
Q9. What is a bus duct (busway) compared with a busbar inside a panel?
- (a) A bus duct is a busbar system enclosed in a metal housing for carrying power over a distance
- (b) A bus duct is a type of fuse
- (c) A bus duct carries only control signals
- (d) A bus duct is the same as a cable tray
Answer: (a) A bus duct is a busbar system enclosed in a metal housing for carrying power over a distance — busways run power through buildings and between switchboards, while panel busbars distribute power inside one enclosure.
Q10. Where in a switchboard are the busbars normally mounted?
- (a) Outside the enclosure, exposed to weather
- (b) In a dedicated busbar chamber, held on insulators
- (c) Inside the circuit breaker mechanism
- (d) Under the floor, buried in concrete
Answer: (b) In a dedicated busbar chamber, held on insulators — busbars sit in their own chamber, supported and separated by insulators so they stay fixed and safely spaced.