Busbar MCQs — Set 1

10 practice questions on what a busbar is, why switchboards use one, and how it differs from ordinary cable.

Q1. What is a busbar in an electrical switchboard?

  • (a) A flexible cable used for earthing
  • (b) A rigid metal bar that distributes power to several circuits
  • (c) A type of circuit breaker
  • (d) An insulating cover for cables

Answer: (b) A rigid metal bar that distributes power to several circuits — a busbar is a common conductor inside a panel or switchboard from which many outgoing circuits are fed.

Q2. What is the main job of a busbar inside a distribution panel?

  • (a) To step voltage up or down
  • (b) To collect incoming power and distribute it to outgoing feeders
  • (c) To measure the load current
  • (d) To protect the panel against lightning

Answer: (b) To collect incoming power and distribute it to outgoing feeders — the incoming supply connects to the busbar, and each outgoing circuit taps off it.

Q3. How does a busbar differ from an ordinary cable?

  • (a) A busbar is rigid and bare, while a cable is flexible and insulated
  • (b) A busbar carries only DC current
  • (c) A cable can carry more current than any busbar
  • (d) A busbar is always buried underground

Answer: (a) A busbar is rigid and bare, while a cable is flexible and insulated — busbars are solid bars mounted on insulators inside an enclosure, whereas cables are flexible insulated conductors.

Q4. Which metal is most commonly used for busbars in switchgear?

  • (a) Iron
  • (b) Aluminium only
  • (c) Copper
  • (d) Lead

Answer: (c) Copper — copper is the usual choice because of its high conductivity, good mechanical strength and reliable joints.

Q5. What is the most common shape of busbar used in low-voltage panels?

  • (a) Hollow tube
  • (b) Round rod
  • (c) Flat rectangular bar
  • (d) Triangular bar

Answer: (c) Flat rectangular bar — flat bars are easy to joint, bolt and cool, so they dominate LV switchboards and panels.

Q6. A three-phase load draws 50 kW at 400 V with a power factor of 0.8. What current must the busbar carry?

  • (a) 45.1 A
  • (b) 62.5 A
  • (c) 90.2 A
  • (d) 125 A

Answer: (c) 90.2 A — I = P ÷ (√3 × V × pf) = 50,000 ÷ (1.732 × 400 × 0.8) = 50,000 ÷ 554 = 90.2 A.

Q7. In a three-phase busbar system, which colours are commonly used to identify the R, Y and B phases?

  • (a) Red, yellow and blue
  • (b) Green, white and black
  • (c) Brown, grey and pink
  • (d) Orange, violet and grey

Answer: (a) Red, yellow and blue — R, Y and B busbars are conventionally painted or sleeved red, yellow and blue for easy identification.

Q8. Why are busbars usually left bare instead of being insulated like cables?

  • (a) Bare bars are cheaper to manufacture
  • (b) Air around the bars plus support insulators give the needed insulation and cooling
  • (c) Insulation would increase the current rating too much
  • (d) Bare bars cannot develop faults

Answer: (b) Air around the bars plus support insulators give the needed insulation and cooling — the air gap and the insulators between bars provide insulation, while the bare surface sheds heat freely.

Q9. What is a bus duct (busway) compared with a busbar inside a panel?

  • (a) A bus duct is a busbar system enclosed in a metal housing for carrying power over a distance
  • (b) A bus duct is a type of fuse
  • (c) A bus duct carries only control signals
  • (d) A bus duct is the same as a cable tray

Answer: (a) A bus duct is a busbar system enclosed in a metal housing for carrying power over a distance — busways run power through buildings and between switchboards, while panel busbars distribute power inside one enclosure.

Q10. Where in a switchboard are the busbars normally mounted?

  • (a) Outside the enclosure, exposed to weather
  • (b) In a dedicated busbar chamber, held on insulators
  • (c) Inside the circuit breaker mechanism
  • (d) Under the floor, buried in concrete

Answer: (b) In a dedicated busbar chamber, held on insulators — busbars sit in their own chamber, supported and separated by insulators so they stay fixed and safely spaced.

Also read: Why Are Transmission Voltages 11 kV, 33 kV, 66 kV and 132 kV? | All MCQ Topics