AC Electrical MCQs — Set 9

10 practice questions on diagnosing common AC faults — work each one out before checking the answer.

Q1. An AC trips the MCB the instant it is switched on. The most likely cause is:

  • (a) A dirty air filter
  • (b) A short circuit in the compressor or its wiring
  • (c) Low refrigerant
  • (d) A blocked drain pipe

Answer: (b) A short circuit in the compressor or its wiring — an instant trip means a very large fault current, which is what a short circuit causes.

Q2. An AC runs for a while, then trips the breaker. A likely cause is:

  • (a) An undersized MCB or a loose, overheating connection
  • (b) A clean air filter
  • (c) A high EER rating
  • (d) A new capacitor

Answer: (a) An undersized MCB or a loose, overheating connection — heat builds up over time until the breaker or the hot joint trips the circuit.

Q3. An AC runs but does not cool the room. The most common cause is:

  • (a) Low refrigerant from a leak
  • (b) A new air filter
  • (c) A higher star rating
  • (d) A longer power cord

Answer: (a) Low refrigerant from a leak — with too little refrigerant the evaporator cannot absorb enough heat from the room.

Q4. What does a dirty indoor air filter cause?

  • (a) Better cooling
  • (b) Reduced airflow, poor cooling and higher power use
  • (c) More refrigerant in the system
  • (d) A tripped RCCB

Answer: (b) Reduced airflow, poor cooling and higher power use — choked airflow stops the coil exchanging heat properly.

Q5. The outdoor unit hums but the fan and compressor will not start. The likely fault is:

  • (a) A failed capacitor
  • (b) A blocked drain pipe
  • (c) A clean air filter
  • (d) A high thermostat setting

Answer: (a) A failed capacitor — without the capacitor’s starting torque the motors hum and stay stalled.

Q6. Ice forms on the indoor evaporator coil. A likely cause is:

  • (a) Too much refrigerant only
  • (b) Low refrigerant or blocked airflow
  • (c) A new remote battery
  • (d) High outdoor temperature

Answer: (b) Low refrigerant or blocked airflow — either one drops the coil temperature below freezing, so moisture in the air turns to ice.

Q7. Water drips from the indoor unit into the room. The usual cause is:

  • (a) A blocked condensate drain pipe
  • (b) Low supply voltage
  • (c) A failed compressor
  • (d) A 5-star rating

Answer: (a) A blocked condensate drain pipe — condensed water cannot drain away, so it overflows into the room.

Q8. An AC keeps tripping the RCCB. This points to:

  • (a) Earth leakage from damaged insulation
  • (b) A dirty air filter
  • (c) Low refrigerant
  • (d) A long copper pipe

Answer: (a) Earth leakage from damaged insulation — the RCCB trips on leakage current flowing to earth, which is what damaged insulation causes.

Q9. You smell burning from the AC. What should you do first?

  • (a) Ignore it
  • (b) Switch the AC off at once and call a technician — a loose or overheated connection is likely
  • (c) Set the temperature lower
  • (d) Pour water on the unit

Answer: (b) Switch the AC off at once and call a technician — a loose or overheated connection is likely — a burning smell means something is overheating, so cut the power before it becomes a fire.

Q10. The compressor runs but the outdoor fan does not. The likely result is:

  • (a) Better cooling
  • (b) The condenser overheats and the unit trips on high pressure
  • (c) Lower power use
  • (d) Ice on the indoor coil

Answer: (b) The condenser overheats and the unit trips on high pressure — with no fan the condenser cannot shed heat, so pressure climbs until the safety cut-out trips.

Also read: Electrical Safety MCQs | All MCQ Topics