AC Electrical MCQs — Set 6
10 practice questions on the AC compressor, starting current and capacitors — work each one out before checking the answer.
Q1. What is the job of the compressor in an AC?
- (a) To blow cold air into the room
- (b) To compress the refrigerant and circulate it through the system
- (c) To filter dust from the air
- (d) To drain water outside
Answer: (b) To compress the refrigerant and circulate it through the system — the compressor is the heart of the refrigeration cycle.
Q2. Compared with running current, the starting current of a compressor motor is:
- (a) About the same
- (b) Lower
- (c) Several times higher
- (d) Zero
Answer: (c) Several times higher — a motor at standstill draws a large inrush current until it spins up.
Q3. What is the job of the start capacitor?
- (a) To store cold air
- (b) To give the motor extra starting torque
- (c) To reduce the supply voltage
- (d) To filter the power supply
Answer: (b) To give the motor extra starting torque — it creates the phase shift the motor needs to start turning.
Q4. What is the job of the run capacitor?
- (a) To keep the motor running smoothly and efficiently
- (b) To start the indoor fan only
- (c) To cool the refrigerant
- (d) To trip the breaker
Answer: (a) To keep the motor running smoothly and efficiently — it stays in circuit while the motor runs and improves its power factor.
Q5. A compressor hums but does not start. What is the most likely cause?
- (a) A dirty air filter
- (b) A weak or failed start capacitor
- (c) A low room temperature
- (d) A blocked drain pipe
Answer: (b) A weak or failed start capacitor — without enough starting torque the motor hums and stays stalled.
Q6. Why does a motor draw very high current at the moment it starts?
- (a) The capacitor is charging
- (b) At standstill there is no back EMF to oppose the current
- (c) The refrigerant is cold
- (d) The thermostat is faulty
Answer: (b) At standstill there is no back EMF to oppose the current — back EMF builds up only as the motor spins, so starting current is high.
Q7. An outdoor fan motor runs very slowly or not at all. A likely cause is:
- (a) A failed fan capacitor
- (b) A dirty indoor filter
- (c) Low refrigerant only
- (d) A high EER rating
Answer: (a) A failed fan capacitor — the fan motor needs its capacitor for torque, and a dead one leaves it slow or stalled.
Q8. What does the compressor overload protector do?
- (a) It increases cooling
- (b) It disconnects the compressor if it overheats or draws excess current
- (c) It cleans the air filter
- (d) It controls the remote
Answer: (b) It disconnects the compressor if it overheats or draws excess current — it protects the motor windings from burning out.
Q9. What is the correct order of the refrigeration cycle?
- (a) Compressor → condenser → expansion valve → evaporator
- (b) Evaporator → compressor → expansion valve → condenser
- (c) Condenser → evaporator → compressor → expansion valve
- (d) Expansion valve → condenser → evaporator → compressor
Answer: (a) Compressor → condenser → expansion valve → evaporator — the compressor pressurises the refrigerant, the condenser releases heat, the valve drops pressure, and the evaporator absorbs room heat.
Q10. What happens inside the condenser coil?
- (a) Refrigerant absorbs heat from the room
- (b) Hot refrigerant releases heat to the outside air
- (c) Refrigerant freezes solid
- (d) Room air is filtered
Answer: (b) Hot refrigerant releases heat to the outside air — the condenser dumps the heat the evaporator picked up indoors.
Also read: AC Circuits MCQs | All MCQ Topics