AC Electrical MCQs — Set 5

10 practice questions on AC running current, MCB size and wiring — work each one out before checking the answer.

Q1. A 1,800 W AC runs on a 230 V supply. What current does it draw?

  • (a) 6.5 A
  • (b) 7.8 A
  • (c) 10.4 A
  • (d) 5.2 A

Answer: (b) 7.8 A — I = P ÷ V = 1,800 ÷ 230 = 7.8 A.

Q2. A 1,500 W AC runs on a 230 V supply. What current does it draw?

  • (a) 5.2 A
  • (b) 6.5 A
  • (c) 7.8 A
  • (d) 8.7 A

Answer: (b) 6.5 A — I = P ÷ V = 1,500 ÷ 230 = 6.5 A.

Q3. A 2,400 W AC runs on a 230 V supply. What current does it draw?

  • (a) 7.8 A
  • (b) 8.7 A
  • (c) 10.4 A
  • (d) 12 A

Answer: (c) 10.4 A — I = P ÷ V = 2,400 ÷ 230 = 10.4 A.

Q4. A 1,200 W AC runs on a 230 V supply. What current does it draw?

  • (a) 4.3 A
  • (b) 5.2 A
  • (c) 6.5 A
  • (d) 7.8 A

Answer: (b) 5.2 A — I = P ÷ V = 1,200 ÷ 230 = 5.2 A.

Q5. A 2,400 W AC draws 10.4 A at 230 V. Which MCB rating is the smallest suitable choice?

  • (a) 6 A
  • (b) 10 A
  • (c) 16 A
  • (d) 32 A

Answer: (c) 16 A — a 10 A breaker is below the 10.4 A running current, so 16 A is the smallest suitable standard rating.

Q6. A room needs 18,000 BTU/hr of cooling. What size air conditioner is needed?

  • (a) 1 ton
  • (b) 1.5 ton
  • (c) 2 ton
  • (d) 0.5 ton

Answer: (b) 1.5 ton — 1 ton of cooling = 12,000 BTU/hr, so 18,000 ÷ 12,000 = 1.5 ton.

Q7. Under the 80% rule, what is the maximum continuous load on a 20 A, 230 V circuit?

  • (a) 2,760 W
  • (b) 3,680 W
  • (c) 4,600 W
  • (d) 1,920 W

Answer: (b) 3,680 W — 20 A × 230 V = 4,600 W, and 80% of 4,600 W = 3,680 W.

Q8. Why should an AC have its own dedicated circuit?

  • (a) It looks neater
  • (b) Its high running and starting current can overload a shared circuit
  • (c) It cools the room better
  • (d) It needs a DC supply

Answer: (b) Its high running and starting current can overload a shared circuit — a dedicated circuit keeps the AC load off other appliances.

Q9. What does a 30 mA RCCB protect against in an AC circuit?

  • (a) Overload only
  • (b) Short circuit only
  • (c) Electric shock from earth leakage
  • (d) Low voltage

Answer: (c) Electric shock from earth leakage — a 30 mA RCCB trips on a small leakage current that could shock a person.

Q10. What happens if the wiring for an AC is undersized?

  • (a) The AC cools faster
  • (b) The wire overheats, voltage drops and there is a fire risk
  • (c) The EER improves
  • (d) Nothing — wire size does not matter

Answer: (b) The wire overheats, voltage drops and there is a fire risk — thin wire has higher resistance, so it heats up under the AC load.